Network and authentication

Network requirements, credential roles and operator privileges.

Network requirements

ConnectionRequirement
Reader → relaystreamzet-embedded.plitsoft.workers.dev · TCP 443 · HTTPS/WSS
Operator browserstreamzet.com · streamzet-embedded.plitsoft.workers.dev · *.supabase.co · HTTPS/WSS
OEM web dashboardxspan.streamzet.com · HTTPS
Inside the readerDashboard traffic reaches loopback TLS 9000; no inbound port forwarding required.

The reader initiates outbound TLS, allowing operation behind NAT. DNS, a correct clock and WebSocket-compatible egress are required. Retain CA and hostname verification.

Credential roles

CredentialPurpose
Enrollment keyEnrolls new readers; does not grant operator terminal or Fleet authority.
Device secretStored in state/identity; unique per reader and used for its connection.
Operator loginAuthorizes terminal, commands and dashboard access after ownership checks.
OEM loginSeparate Basic authentication for the original RFID dashboard.

Privileges and authentication boundaries

Shells run with the installed agent’s OS privileges. The qualified reader’s OEM environment runs as root. The OEM must choose and qualify the deployment UID and file access scope.

The RFID UI uses a separate web origin from the StreamZet console. A one-use launch ticket and HttpOnly session cookie protect access; operator Bearer tokens are not forwarded to the reader. Dashboard traffic travels only over the reader’s own connection, authenticated with its per-device secret, and changes to the reader’s HTTPS certificate are recorded on the server.